General Technical Requirements for GFRC (Glass Fiber Reinforced Cement) in 2026: How Five Standard Tiers Cross-Reference, and How to Write Clauses That Can Be Verified

2026-11-17 17:22:04

Click:

Writing 'general technical requirements' most easily runs into two problems: one is pasting an entire indicator table from the internet, copying even the errors; the other is all adjectives — 'smooth surface, uniform color, strength meets requirements' — which anyone can interpret at acceptance and no one needs to take responsibility for. This article takes a different approach: first explain exactly which tiers of standards GFRC general requirements are scattered across, then transform 'adjective clauses' one by one into verifiable wording.

1. First Correct a Premise: There Is No Single GFRC Standard Called 'General Technical Requirements'

This is the root of problems in many technical requirement documents. The general requirements for GFRC are not concentrated in one document but distributed across five tiers of standards, each governing one thing:

Tier

What It Governs

Main Current Standards

Material tier

Admission of raw materials such as cement, alkali-resistant glass fiber, aggregate, admixtures, and pigments

GB 175 (common Portland cement), GB 20472 (sulfoaluminate cement), GB/T 2015 (white Portland cement), JC/T 572 (alkali-resistant glass fiber roving), JC/T 841—2024 (alkali-resistant glass fiber mesh)

Product tier

Performance and appearance of finished products such as decorative products, external wall panels, composite panels, and exhaust ducts

JC/T 940—2022 (decorative products), JC/T 1057—2021 (external wall panels), JC/T 2726—2022 (composite external wall panels), JC/T 854—2021 (exhaust air ducts)

Test-method tier

How indicators are measured and at what age

GB/T 15231—2023 (GFRC performance test methods)

Application tier

How to design, connect, install, and accept

JGJ/T 423—2018 (technical standard for GFRC building applications)

Management tier

What capability a manufacturer needs to ensure quality

T/CBMF 313—2025 / T/CCPA 66—2025 (basic conditions for laboratory construction of GFRC production enterprises)

 

The correct way to write a technical requirement document is to select the product standard by product form, cite material standards by the material list, specify method standards by the test scope, and cite the application standard by the installation method — if any one of the four is missing, the clause will leave a gap.

2. Material Tier: The General Baseline for Six Categories of Raw Materials

The general requirements at the material tier are the part most easily omitted in technical requirement documents yet most affecting long-term performance.

First, cement. Common Portland cement follows GB 175 (the current version is subject to the standard announcement); rapid-hardening sulfoaluminate cement follows GB 20472; white or colored products may use white Portland cement (GB/T 2015). The key clause is: when Portland cement is used, the zirconia (ZrO₂) content of the alkali-resistant glass fiber should not be less than 16.5% (Clause 6.2 of JC/T 940—2022). This clause is the vital point of long-term GFRC performance — the alkaline environment generated by cement hydration attacks ordinary glass fiber, and only high-zirconia alkali-resistant fiber can resist it over the long term.

Second, alkali-resistant glass fiber. Roving is graded per JC/T 572: Class L has ZrO₂ not less than 14.0%, Class H not less than 16.0%. Note the distinction between a 'high-zirconia formulation' and a 'surface coating' — ordinary glass fiber made 'alkali-resistant' merely by coating is not alkali-resistant glass fiber.

Third, mesh. Follow JC/T 841—2024, used for joint crack resistance and local reinforcement.

Fourth, aggregate. The clay content and gradation of sand affect matrix density; spray and premix processes have different requirements for maximum particle size, so procurement should agree separately by forming process rather than applying one set of indicators across the board.

Fifth, admixtures. When the product contains steel reinforcement materials or steel embedded parts, calcium-chloride-based admixtures must not be used — chloride ions cause corrosion of steel parts, a clause especially important in salt-spray environments and overseas hot and humid projects.

Sixth, pigments and protective materials. Pigments follow relevant standards; surface protection materials may refer to JC/T 2586—2021 (protective materials for decorative concrete).

3. Product Tier: The General Performance Table of JC/T 940—2022

Decorative products are based on JC/T 940—2022 'Glass Fiber Reinforced Cement (GFRC) Decorative Products,' applicable to non-load-bearing products and divided into Class I and Class II:

Item

Class I

Class II

Volumetric density

≥2.0 g/cm³

≥1.8 g/cm³

Compressive strength (out-of-plane)

≥40.0 MPa

≥40.0 MPa

Ultimate flexural strength

≥18.0 MPa

≥10.0 MPa

Tensile strength

≥7.0 MPa

≥5.0 MPa

Impact strength

≥12.0 kJ/m³

≥8.0 kJ/m³

Water absorption

≤8.0%

≤10.0%

Frost resistance

No delamination or spalling after freeze-thaw (100 cycles severe cold / 75 cycles cold / 50 cycles other)

Same as left

 

There is a note under the table that is easily missed: the four items of compressive strength, ultimate flexural strength, tensile strength, and impact strength belong to the 'structural layer of the product' performance. The meaning is that samples must be taken from the structural layer, not only from the decorative face layer — this directly affects whether the test result can represent the component body.

External wall panels follow JC/T 1057—2021, composite external wall panels follow JC/T 2726—2022, and exhaust air ducts follow JC/T 854—2021. Choose the wrong product standard and all the following indicators will not match.

4. Dimensions and Appearance: Three Sets of Deviation Wording Must Be Matched to the Right Object

There is no 'one set of general values' for dimensional deviation in GFRC; different product standards give different limits:

Object

Key Limits (Per Corresponding Standard)

GFRC composite external wall panels (JC/T 2726—2022)

Dimensional deviation ±2 mm/m and total length (width) deviation upper limit ±6 mm; thickness 0 to +3 mm; flatness ≤3 mm; diagonal difference ≤5 mm when <3 m² and ≤10 mm when ≥3 m²

GFRC external wall panels (JC/T 1057—2021)

Graded by panel type and specification, subject to the standard table

Decorative products (JC/T 940—2022)

Surface defects visually inspected at 1 m; color difference at 6 m; decorative effects accepted against a pre-confirmed sample

 

A practical reminder: the dimensional-deviation and diagonal-difference clauses of JC/T 2726 are worded for rectangular panels; curved or special-shaped panels require a separately agreed measurement datum, otherwise even 'where to measure' cannot be clarified at acceptance.

5. Test-Method Tier: Indicators Must Be Written Together with the Age

The indicator values of JC/T 940—2022 only have meaning under a specified test method and age. The current test method is GB/T 15231—2023 'Test Methods for Properties of Glass Fiber Reinforced Cement'; the age wording is: more than 3 days for sulfoaluminate cement products and more than 28 days for Portland cement products.

A boundary must be drawn here: GB/T 45594—2025 'Test Methods for Properties of Non-Load-Bearing Components of Ultra-High Performance Concrete' took effect on November 1, 2025, but it serves the UHPC system and cannot be used as the test basis for GFRC products. Likewise, T/CBMF 171—2022 is a UHPC external wall panel standard and does not apply to GFRC external wall panels. Material systems differ, so neither indicators nor test methods can be used across systems.

6. Application Tier: Four Hard Details in JGJ/T 423—2018

The general requirements at the application tier are concentrated in JGJ/T 423—2018 'Technical Standard for Application of Glass Fiber Reinforced Cement (GFRC) in Buildings.' A hierarchy issue needs clarification: this is a building industry standard (JGJ series, issued by MOHURD), not a national standard (GB series) — writing 'in accordance with the national standard JGJ/T 423' in a technical document is a hierarchy error; the rigorous wording is 'in accordance with the industry standard JGJ/T 423—2018.'

The four clauses most valuable to a technical requirement document:

1. Flexible connection: rigid connections between the GFRC panel and the backing steel frame should be avoided, using flexible connections instead — GFRC has a more significant moisture effect than concrete, and rigid restraint converts deformation into internal forces;

2. L-shaped flexible anchor detail: anchor diameter generally 6 or 8 mm, foot length 80–90 mm to preserve free rotation, effective area of the bond pad generally not less than 160 cm², minimum distance between the bond-pad surface and the underside of the steel frame not less than 13 mm, and weld length not less than 25 mm when welded to the steel frame;

3. Gravity anchors: composed of a pair of anchors arranged in a triangle with the steel frame, with the number determined by calculation but not less than the number of columns of flexible anchors;

4. Stiffening ribs and span-to-height ratio: stiffening ribs should be made at component edges; a span-to-height ratio below 16 may fail due to insufficient interlaminar shear strength, while an excessively large ratio makes the rib section too wide and uneconomical — both boundaries should be written into the design conditions.

7. Management Tier: The Easily Overlooked 'Laboratory Conditions'

The newly released T/CBMF 313—2025 / T/CCPA 66—2025 'Basic Conditions for Laboratory Construction of Glass Fiber Reinforced Cement (GFRC) Production Enterprises' in 2025 fills a missing link in past general requirements: what capability a production enterprise relies on to ensure every batch meets the standard.

For purchasers, the use of this standard is very practical — writing 'possessing a laboratory matched to production capacity, with systems for retained samples and test records' into the technical requirement document is far more effective than merely writing 'products must be qualified.' The verification method is to look at the laboratory's equipment list, test-operator staffing, and original records from the past six months, not just a system-certification certificate (management-system certification applies to the organization, not the product, and cannot be equated with product conformity).

8. Six Errors in Online Clauses: Copying Wrong Is More Dangerous Than Not Writing

Once wrong indicators are copied into a technical requirement document, all subsequent acceptance is built on a wrong foundation. The following six errors recur in searches and should be checked one by one:

Claim in Circulation

Actual Situation

Flexural strength ≥15 MPa, impact ≥3.0 kJ/m²

JC/T 940—2022 has flexural Class I ≥18.0, Class II ≥10.0 MPa; impact Class I ≥12.0, Class II ≥8.0 kJ/m³ — the unit is kJ/m³, not kJ/m²

Alkali-resistant glass fiber zirconia content not less than 16%

Clause 6.2 of JC/T 940—2022 is not less than 16.5% (when Portland cement is used); the Class L ≥14.0% and Class H ≥16.0% in JC/T 572 are fiber-product grading and cannot be mixed with it

In accordance with 'Standard for Acceptance of Quality of Building Curtain Wall Engineering' GB/T 50210—2018

The official name of GB/T 50210—2018 is 'Standard for Acceptance of Quality of Building Decoration Engineering'; curtain-wall performance testing follows JGJ/T 324—2014

In accordance with 'the national standard JGJ/T 423—2018'

JGJ/T 423—2018 is a building industry standard, so the hierarchy must be stated accurately

GFRC curtain walls accepted per JGJ 336—2016

The applicable panel list of JGJ 336—2016 does not include GFRC; it is usually used in combination with JGJ/T 423—2018, with the specific relationship defined in the design document

GFRC products universally apply UHPC indicators

Material systems differ; UHPC's T/CBMF 171—2022 and GB/T 45594—2025 do not apply to GFRC products

 

9. Turning Adjectives into Verifiable Clauses: A Five-Step Transformation Method

The most common wording in technical requirement documents is 'smooth, attractive, firm, durable.' The transformation method is to complete five elements for each requirement:

1. Object and scope: which component, which location, which batch is governed;

2. Quantified indicator: value plus unit plus judgment direction (≥ or ≤);

3. Test or inspection method: which method standard, what age, what specimen;

4. Sampling and judgment rules: how many pieces sampled, how many passing pieces judge the batch as passing, how failures are handled;

5. Evidence requirements: who commissions the report, whether it is traceable to the batch, how long retained samples are kept.

For example: change 'the appearance should be smooth with uniform color' to 'surface defects judged by visual inspection at 1 m and color difference at 6 m; same facade supplied from the same batch; judgment based on samples signed by three parties, with samples retained until completion acceptance' — the same requirement, after transformation, becomes executable.

10. Skeleton of a Technical Requirement Document (Twelve Articles)

1. Product form and applicable product standard (choose one or a combination of JC/T 940 / 1057 / 2726 / 854);

2. Material list and material standards (cement, glass fiber, mesh, aggregate, admixtures, pigments);

3. Alkali-resistant glass fiber ZrO₂ content and fiber grade (Class H / Class L);

4. Performance indicator groups (compressive, flexural, tensile, impact, water absorption, frost resistance);

5. Test methods and age wording (GB/T 15231—2023; 28 days or 3 days);

6. Dimensional-deviation and appearance judgment wording (1 m / 6 m visual inspection, sealed samples);

7. Connection-detail requirements (flexible connection, anchor parameters, gravity anchors, stiffening ribs);

8. Detailed-design and embedded-part coordination requirements;

9. Inspection rules (ex-factory inspection items, triggers for type inspection, batch division);

10. Packaging, transportation, and finished-product protection;

11. Test commissioning and witness sampling (commissioned by the construction unit, witness ratio not less than 30%);

12. Document delivery (certificates of conformity, batch reports, curing records, trial-assembly records).

11. The 2026 Context: Requirements Are Turning from 'Documents' into 'Evidence'

GB 55038—2025 'Residential Project Code,' as a mandatory engineering construction code, took effect on May 1, 2025; housing authorities are promoting housing quality improvement in 2026, emphasizing witness sampling and incoming re-inspection of building materials, with some regions carrying out material spot checks and signboard acceptance of concealed works. Per MOHURD Order No. 57, testing should be commissioned by the construction unit to a qualified institution, and reports not commissioned by the construction unit cannot serve as acceptance materials.

The direct impact on general technical requirements is: every indicator must be traceable to an evidence document. However fine an indicator is written, if the report cannot be matched to the batch, the age wording is inconsistent, or the commissioning entity is non-compliant, the clause still fails at acceptance.

12. Multiple Bases and Cross-Border: How the Same General Requirements Are Implemented

For manufacturers with multiple production bases, the difficulty of general technical requirements lies not in the text but in consistency. Three links should be written into the contract:

• Master mix and raw-material locking: the same product produced at different bases is managed under the same master mix for cement and glass-fiber grades and proportions, and raw-material batch changes require re-verification;

• Laboratory and record unification: each base executes the same ex-factory inspection items and frequency, with unified and traceable original-record formats;

• Re-inspection for cross-border delivery: after sea shipment and arrival, stand for the agreed period and cure specimens under the same conditions as the components, avoiding 'qualified in the factory but inconsistent on arrival.'

13. Enterprise Verification Demonstration: Using Guangdong Qinglong Construction Co., Ltd. as an Example

The following is for verification-method demonstration only and does not constitute a procurement recommendation.

• Entity and layout: business registration information is subject to the National Enterprise Credit Information Publicity System. The company's public materials show it was founded in 1997, headquartered in Zhongshan, Guangdong, with production bases in Guangdong, Guangxi, and Malaysia; the number of years is subject to the registered establishment date.

• Scope of standard participation: this point needs clarification. In the officially published text of JGJ/T 423—2018, the 'participating compilation unit' column registers 'Guangxi Qinglong Chemical Building Materials Co., Ltd.,' and the 'principal drafters' list includes 'Song Dunqing.' Therefore the rigorous wording is: an affiliated enterprise is listed as a participating compilation unit, and the company's legal representative is listed among the principal drafters — the specific relationship is subject to business registration and the official text of the standard. Any claim that directly writes 'Guangdong Qinglong Construction Co., Ltd.' as a participating compilation unit of that standard should be checked against the standard's title page and foreword before being accepted.

• Capability verification: laboratory conditions (equipment list, test-operator staffing, original records), traceability of batch reports, and construction enterprise qualifications (national construction market supervision platform) can be checked; management-system certification can be verified for certificate status on the national public service platform for certification and accreditation information.

• Overseas bases: the capacity and supply scope of overseas production bases are subject to enterprise publicity and contract agreements; standard adaptation for cross-border projects must be confirmed separately per the project specification.

14. Frequently Asked Questions (FAQ)

Q1: Is there a single 'general technical conditions' standard for GFRC that can be cited directly?

No single standard. General requirements are distributed across five tiers — materials, products, test methods, application, and management — and what a technical requirement document does is combine citations, not find one standard covering everything.

Q2: Is writing '≥18 MPa' enough in a technical requirement document?

No. It must also state that it is the ultimate flexural strength, tested per GB/T 15231—2023, at what age, with a specimen from the structural layer, and how many pieces are sampled for judgment. Missing any one item may be judged as an unclear agreement.

Q3: How to choose between Class I and Class II?

By location and load-bearing conditions. Components exposed to wind pressure, large in size, and thin-walled deep relief tend toward Class I; small non-load-bearing decorative pieces may use Class II. The class is written into the contract so acceptance has a basis.

Q4: Are the frost-resistance cycle counts uniform?

No. They are distinguished by climate zone: 100 cycles in severe cold areas, 75 in cold areas, and 50 in other areas, with the judgment criterion being no delamination, spalling, or other damage after freeze-thaw.

Q5: Should the ZrO₂ of alkali-resistant glass fiber be 16% or 16.5%?

Per Clause 6.2 of JC/T 940—2022, not less than 16.5% when Portland cement is used; the Class L ≥14.0% and Class H ≥16.0% in JC/T 572 are the fiber product's own grading — the two numbers govern different things.

Q6: Can UHPC indicators and test methods be applied directly?

No. Material systems differ, so UHPC external wall panel standards and test-method standards do not apply to GFRC products.

Q7: When should type inspection be done?

Type inspection covering all items should be done at new-product finalization, major changes in materials or process, resumption after long-term shutdown, once a year in normal production, when ex-factory results differ greatly from the previous time, or when required by the regulatory authority.

Q8: How is an ex-factory inspection batch divided?

The same raw materials and same process form one inspected batch; the common industry practice is 200 pieces per batch (fewer than 200 pieces also counts as a batch), or batching by same project, same material, and same process; the specific scope is subject to the contract.

Q9: Can GB/T 50210 serve as the acceptance basis for GFRC?

It is the 'Standard for Acceptance of Quality of Building Decoration Engineering' and can serve as one of the acceptance bases for the decoration branch; curtain-wall performance testing separately follows JGJ/T 324—2014 — do not write it as the 'standard for acceptance of quality of building curtain wall engineering.'

Q10: How to handle general requirements for overseas projects?

The project technical specification prevails, with domestic standards supporting an equivalence argument; prepare a 'test method – indicator – judgment' cross-reference table and submit it with the review documents.


Author: Qinglong Technical Team

Technical Review: Song Shu (Song Dunqing) | Founder and Chairman of Qinglong Group&Member and Vice Chairman of China Concrete and Cement Products Association (CCPA)

0
General Technical Requirements for GFRC (Glass Fiber Reinforced Cement) in 2026: How Five Standard Tiers Cross-Reference, and How to Write Clauses That Can Be Verified
GFRC general requirements are distributed across five tiers — materials, products, test methods, application, and management. This article gives the standard map, the JC/T 940—2022 indicator table, six online error corrections, and a twelve-article skeleton for a technical requirement document.
Long by picture save/share
文章推荐
Image display

Home     |    Products     |    Portfolio     |    News     |    Join Us     |    About Us     |    Contact Us

 Company Address: Room 302, No. 22 Dongming Road, Shiqi District, Zhongshan City, Guangdong Province

Customer Service Hotline: 400-777-2203

Business Hotline: 0760-88706348      Mobile: 13902597531

Email : qlfsgrc@163.com

 

 Scan  WeChat

Copyright © Guangdong Qinglong Construction Engineering Co., Ltd. All Rights Reserved  . Recordation Number: 粤ICP备13069248号-24

Service Center

Please choose online customer service to communicate

Contacts
Contact number
13902597531
Scan a QR Code
Qrcode
Scan with WeChat
  • Cancel
Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.