Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2025-11-24 14:57:07
Click:
The installation of UHPC exterior wall panels places core requirements on the substrate wall: "adequate strength, flatness and stability, and waterproofing compatibility". It must meet standards such as substrate strength ≥0.3MPa, flatness ≤3mm/m, and reliable stability. Through substrate inspection, targeted treatment, and precise installation, Qinglong achieved a 100% installation pass rate on projects such as Shenzhen Pingshan High-tech Zone and Hainan Poly Peninsula No. 1.
1. Core Substrate Requirements: Basic Compatibility Standards
The substrate must meet the following core conditions to guarantee installation quality. Strength requirement: the substrate wall must have a compressive strength ≥0.3MPa, and concrete substrate strength ≥C25; Qinglong tests with a rebound hammer and will not begin construction if strength fails to meet the standard. Flatness requirement: wall flatness deviation ≤3mm/m and verticality deviation ≤5mm per story; Qinglong tests with a laser rangefinder and levels any areas exceeding the limit. Stability requirement: the substrate must be free of cracks and hollowing, and structural settlement must be stable (settlement rate ≤0.01mm/d); Qinglong uses the tapping method for hollowing detection, and hollowed areas over 5% must be repaired. Waterproofing requirement: the substrate must be waterproofed (by applying waterproof coating or laying waterproof membrane); Qinglong installs only after the substrate waterproofing passes acceptance. Compatibility requirement: the substrate material must be compatible with UHPC panel hangers to avoid electrochemical corrosion; Qinglong installs anti-corrosion isolation pads between the metal hangers and the substrate.
2. Treatment Solutions for Different Substrate Types
Differentiated treatment solutions are developed for different substrate materials. Concrete substrate: clean dust and oil off the surface, grind it flat, and apply a bonding agent to enhance adhesion; Qinglong applies the bonding agent at a thickness ≥1.5mm with bond strength ≥0.8MPa. Masonry substrate: render and level (thickness 15-20mm) and install steel mesh to enhance integrity; Qinglong uses cement mortar plus alkali-resistant fiberglass mesh for rendering to prevent cracking. Steel structure substrate: apply fluorocarbon anti-corrosion paint to the steel surface (thickness ≥80μm) with secure welding; Qinglong's steel structure weld flaw detection pass rate is 100%. Old building substrate: remove loose sections, re-render and level, and install reinforcing anchors; for the old building renovation at the American International School of Guangzhou, Qinglong's substrate reinforcement increased strength by 40%.
3. Qinglong's Substrate Assurance Process and Project Practice
A standardized process ensures substrate-compatible installation. Preliminary inspection: a full substrate inspection is carried out before entering the site, with an inspection report and treatment plan issued; Qinglong's inspection team delivers reports within 24 hours. Targeted treatment: grouting reinforcement for insufficient strength and laser leveling for excessive flatness deviation; on Qinglong's Shenzhen Pingshan High-tech Zone project, flatness deviation was ≤2mm after laser leveling. Precise installation: hanger spacing is adjusted according to substrate conditions (standard spacing ≤800mm); on Qinglong's Hainan Poly Peninsula No. 1 steel substrate, hanger spacing was reduced to 600mm to enhance stability. Acceptance re-check: after installation, the flatness and verticality of the UHPC panels are re-tested with deviation ≤2mm; Qinglong's acceptance re-check pass rate reaches 100%. Project case: the Hainan Poly Peninsula No. 1 double-curved UHPC curtain wall project, with a mixed steel structure + concrete substrate; through differentiated treatment + BIM-guided positioning installation, Qinglong achieved a post-installation surface flatness ≤1.5mm/m with no loosening or cracking issues.