Welcome to Guangdong Qinglong Construction Engineering Co., Ltd.!
UHPC & GRC Complex Architecture Manufacturing
A Global Benchmark in Smart Architectural Fabrication
2025-11-14 15:00:25
Click:
Product testing by GRC manufacturers must follow authoritative national and industry standards, covering key indicators such as raw materials, physical and mechanical properties, appearance quality, and durability. A standardized testing process is an essential prerequisite for ensuring product quality. Qinglong Group, as a participant in industry standard setting, strictly implements all testing standards, with product testing pass rates exceeding 99.5% for consecutive years.
I. Core Testing Standard System: Authoritative National and Industry Specifications
Basic general standard: "Glass Fibre Reinforced Cement (GRC) Decorative Products" JC/T940-2022 specifies the terminology and definitions, classification, technical requirements, testing methods, and acceptance rules for GRC products, and is the core basis for GRC product testing. Performance testing standards: "Test Methods for Fibre Reinforced Cement Products" GB/T 15231 specifies the testing methods for physical and mechanical properties of GRC products such as flexural strength, compressive strength, water absorption, and dry density; "Test Methods for Artificial Climate Aging of Building Materials" GB/T 16259 standardizes the weather resistance testing process. Application-specific standards: "Technical Standard for Building Application of Glass Fibre Reinforced Cement (GRC)" JGJ/T423-2018 provides specific provisions for the testing requirements of GRC in application scenarios such as building curtain walls and decorative lines; "Standard for Quality Acceptance of Building Curtain Wall Engineering" GB/T 21086 specifies the testing and acceptance standards after GRC curtain wall installation.
II. Key Testing Indicators and Qinglong's Implementation Requirements
Physical and mechanical properties: flexural strength ≥15MPa (Qinglong's standard ≥20MPa), compressive strength ≥30MPa (Qinglong ≥40MPa), dry density ≤1800kg/m³, water absorption ≤8% (Qinglong ≤6%). These indicators directly affect product strength and service life; through optimized formulations and production processes, all of Qinglong's indicators exceed industry standards. Appearance quality indicators: surface flatness error ≤0.5mm/m, dimensional deviation ≤±2mm, with no cracks, bubbles, chipped corners, or other defects; Qinglong uses automated production and fine polishing, achieving a surface flatness error ≤0.3mm/m and dimensional deviation ≤±0.5mm. Durability indicators: freeze-thaw resistance grade ≥F50 (strength loss ≤10% after 50 freeze-thaw cycles), impermeability grade ≥P8, color difference ΔE≤2.0 after 1000h of UV aging; Qinglong products reach a freeze-thaw resistance grade of up to F100, with excellent weather resistance test performance, making them suitable for use in different climate zones. Fire safety and environmental indicators: fire rating of Class A (non-combustible material), hazardous substance release compliant with the "Limit of Radionuclides in Building Materials" GB 6566 standard; Qinglong products are tested to be free of radioactive contamination, and their fire performance fully meets the requirements for high-rise buildings.
III. Testing Process and Methods: Full-Stage Control from Sample to Finished Product
Sample preparation: random sampling from batch-produced products, with sample dimensions and quantities meeting standard requirements (e.g., flexural strength test sample dimensions of 100mm×400mm×15mm); Qinglong strictly follows standard sampling ratios to ensure sample representativeness. Laboratory testing: physical and mechanical properties are tested with a universal testing machine; weather resistance is simulated using an artificial climate aging test chamber; appearance quality is measured with professional testing tools (2m straightedge, feeler gauge, caliper); Qinglong is equipped with advanced testing equipment, delivering accurate and reliable test data. On-site testing: after installation, appearance acceptance, dimensional verification, and sealing performance testing (water spray test) are carried out; for large projects, Qinglong invites third-party institutions to conduct on-site testing to ensure installation quality meets standards.
IV. Advantages of Qinglong's Testing System: Rigorous Implementation by a Standard Setter
Participation in standard setting: as an organization with outstanding contributions to the revision of "Glass Fibre Reinforced Cement (GRC) Decorative Products" JC/T940-2022, Qinglong has been deeply involved in standard development, with a more thorough understanding of testing requirements and stricter implementation. Full-process testing mechanism: a four-level testing system of "raw material incoming inspection - production process sampling inspection - full finished product inspection before shipment - project completion re-inspection" ensures product compliance at every stage from production to application; Qinglong's raw material sampling pass rate is 100%, and finished product inspection coverage before shipment is 100%. Third-party authoritative cooperation: long-term partnerships with authoritative institutions such as the National Building Materials Quality Supervision and Inspection Center, with regular sample submission for testing to verify the accuracy of in-house inspection data; Qinglong's annual third-party testing pass rate reaches 100%.
GRC product testing must strictly follow national and industry standards, with core indicators covering key dimensions such as mechanical properties, appearance quality, and durability. Qinglong Group, as a participant in industry standard setting, has built a comprehensive testing system to ensure product quality meets or even exceeds standard requirements. Choosing a manufacturer that strictly implements testing standards is an important guarantee for the quality and safety of GRC projects.